
Product Code: 2120
Emerson PACSystems RSTi-EP I/O modules connect to and are powered by an RSTi-EP network adapter, up to 64 per adapter. They are compact and high-density modules, with up to 16 inline wire connections. Available in 4, 8, or 16 inputs, which are primarily used to receive binary control signals from sensors, transmitters, switches, or proximity switches. They are fully compliant with IEC 61131 and compatible with type-1 and type-3 sensor inputs. Available in 4, 8 or 16 outputs, which are primarily used for the incorporation of decentralized actuators. They are designed for DC-13 discrete outputs according to DIN EN 60947-5-1 and IEC 61131-2 specifications. Available in 4 or 8 inputs, up to 16-bit resolution, and an accuracy of 0.1% FSR (except EP-3124 which is 0.25% FSR). The parameters for the measurement range can be individually set for each channel. With optional diagnostics selection, you’ll get channel specific error messages. Control up to 4 analog actuators with voltage (±10, ±5, 0 to 10, 0 to 5, 2 to 10, or 1 to 5V) or current (0 to 20 or 4 to 20mA). The resolution is 16-bit per channel. An output can be connected to each connector and the internal switching is carried out automatically. With optional diagnostics selection, you’ll get channel specific error messages. Available with 1 or 2 inputs for creating safety segments within your RSTI-EP I/O system, rated SIL 3 compliant (IEC 62061 and EN ISO 13849-1, category 4, PL e). They use contact-based safety transducers and/or safety transducers with OSSD (Output Signal Switching Device) inputs to disconnect the 24VDC output current path from all following modules until the next EP-7641 power module. Restoring the supply power to those modules can be set to automatic or manual. With automatic start, the current path is immediately switched on after resetting the safety circuit(s); with manual, you have to hold the start button for a preset length of time. A delay module option is also available so that you can program some buffer time before shut off (to shut down a machine in a controlled manner, for example). The delay time can be set in four steps between 0 and 60 seconds.
DH-Budenberg CPB3500 Pneumatic Deadweight Tester
Accurate Thermal Systems FTBLL27 Fluidized Temperature Baths
Waygate Technologies Probe Tips
Fluke 3130 Pressure Calibrator
Megger Detex Phasing Tester
E+H Liquiphant FTL51B Level Switch
Fisher 912 Series LP-Gas Pressure Regulator
Pyxis SP-350P and SP-380P Fluorometers
Rosemount 8800D Series Vortex Flow Meter
Bently Nevada 190501 CT Velomitor Velocity Transducer
Extech 380460 Precision Milliohmmeter
Rotronic HygroGen2 Humidity and Temperature Generator
Fluke 323 True RMS Clamp Meter
Druck DPI 104 Calibration Kit
Extech 480400 3-Phase Rotation Tester
Bently Nevada 330400 / 330425 Accelerometer